HS-150IS 每 Side Exit 每 Integral Oversheathed Silicon Cable Intrinsically Safe Accelerometer
Previous | 20 / 25 | Next |
- Hansford Hazardous Area Intrinsically Safe Accelerometer Single Output 3 Core Silicon Cable with Protective Over-Sheath
- Hansford 100mV/g AC acceleration output via Silicon Cable with Protective Over-Sheath
- Hansford AC Accelerometer HS 150IS Series Shear Crystal Construction _ For use with data collector
Key Features
- Intrinsically Safe with European, USA, Indian and Australian approvals
- Side entry for easy access
- For use with data collector
- Shear Crystal Construction
Industries
Building services, Pulp and Paper, Mining, Metals, Utilities, Automotive, Water, Pharmaceutical
Applications
Fans, Motors, Pumps, Compressors, Centrifuges, Conveyors, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, VAC, Spindles, Machine Tooling, Process Equipment
Mounted Base Resonance |
26 – 34 Khz |
---|---|
Sensitivity |
±10%, 10mV/g, 30mV/g, 50mV/g, 100mV/g, 250mV/g, 500mV/g, Nominal 80Hz at 22°C / 72°F |
Operating Temperature Range |
Ex ia I Ma (-55°C ≤ Ta ≤ +103°C) (Mining), Ex ia IIC T4 Ga (-55°C ≤ Ta ≤ +103°C) (Gas, Ex ia IIC T6 Ga (-55°C ≤ Ta ≤ +57°C) (Gas), Ex ia IIIB T110°C Da (-55°C ≤ Ta ≤ +57°C) (Dust), Ex ia IIIB T145°C Da (-55°C ≤ Ta ≤ +92°C) (Dust), Ex ia IIIC T135°C Da (-55°C ≤ Ta ≤ +70°C) (Dust) |
Sealing |
IP68 |
EMC |
EN61326-1:2013 |
Case Material |
Stainless Steel |
Sensing Element/Construction |
PZT/Shear |
Weight |
205gms/ 7.2 oz (nominal) body only |
Screened Cable Assembly |
Silicon – length to be specified with order |
Top/Side Entry |
Side Entry |
Feature |
Intrinsically Safe |
Design |
Premium |
Connector/Cable Type |
3 Core Silicon Cable with Protective Over-Sheath |
Output |
Single Output |
Axis |
Single (Standard) |